Technical data motor
Maingroup |
Electric motors |
Subgroup |
Aluminum motors |
General specs |
|
Motorsize |
90L |
Power |
1.5 [kW] |
Poles |
4 |
Mounting |
Flange B5 |
Efficiency class |
IE2 |
Voltage |
230/400V50Hz |
Electrical specs |
|
Rated current In – 250V |
3.4 [A] |
In 380-420V |
– [A] |
Ist/In |
7.3 |
η – 100% |
82.8 |
η – 75% |
82 |
η – 50% |
79.2 |
cos φ |
0.75 |
Mechanical specs |
|
Rated rpm |
1440 [rpm] |
T |
– [A] |
Tst/Tn |
3.5 |
Tmax/Tn |
4 |
Jmot |
3.65 10-3 kgm²] |
LpA |
55 [dB] |
Weight |
18 [kg] |
IP class |
IP55 |
Housing material |
Aluminum |
Variable frequency drive compatible |
Yes |
Brake |
|
Brake prepared |
No |
Brake torque |
N.A. [Nm] |
Optional brake torque |
N.A. [Nm] |
Brake voltage |
N.A. [V] |
Zl |
N.A. [c/h] |
Options motor
In addition to the standard motor design, it is possible to add options to the motor.
- Temperature sensor (PTC or clixon)
- Forced cooling
- Aberrant voltages
- Increased IP class
- Special motorflanges
- Standstill heating
- TENV
- CSA, UL certificates
- Coating
It is also possible to complete your motor or drive with additional products like:
- An encoder to track the motor rpm also see JRSB encoder
- A variable frequency drive also see JI VFD
Electric motors are designed to use till 1000 meter above NAP and with a max temperature of 40 °C. If a motor is compatible with divergent evironmental factors the type plate will be marked.
In general all electric motors are IP55 rated according to guideline IEC60034-5. The standard motor design is suited for horizontal indoor use or covered outdoor use.
Additional motor protection is necessary when the work environment of the motor is:
- Uncoverd outdoor use
- Dusty environment
- Agressive environment (gasses, vapour or dust)
- Sea climate
- Termites or other vermin
- Vertical use
Additional motor protection can be:
- Rain canopy
- Additional seals or drain holes (for vertical usage)
- Special coating
- Additional protection of the windings with tropical insulation
- stand still heating (for the motor windings)
- Additional drain holes for dissipation of condensate
- Additional bearings (for vertical usage)
Please contact Euronorm technical supportteam to find the right solution for you.
Download
Download product CAD files, catalogue, manual or data below.